PRODUCTS
FOR CAST RESIN / DRY TYPE TRANSFORMERS |
|
This series of controllers are designed for safe operation of medium voltage cast resin / dry type transformer. It is suitable for control room as well as marshalling box installation and is built for long and trouble-free operation under extreme conditions of services associated with transformer.
|
|
|
|
Parametric Comparative Data.
|
Frequently Asked
Questions. |
|
|
|
Transformer Protection
Relay (WTI)
|
|
|
TR-7543 |
|
|
|
- |
Single channel µC based winding temperature indicator. |
- |
Compact design with flush mounting on panel in control room or
inside marshalling box. |
- |
Three potential free C/O contacts for High Temperature Alarm,
Trip & to warn against open or wrong sensor connections. |
- |
One potential free NO contact for fan operation. |
- |
Fully user programmable with self-test facility. |
- |
Options of different auxiliary supply voltages. |
- |
Combicon connectors for ease of wiring. |
|
|
|
|
|
|
Top |
|
|
|
|
|
|
|
|
|
|
|
|
Transformer Protection Relay (WTS)
|
|
|
TR-7544 |
|
|
|
- |
Four
channel µC based winding temperature scanner. |
- |
Designed for monitoring temperature of all the three phase
windings and core of medium voltage cast resin / dry type
transformer. |
- |
Compact design with flush mounting on panel in control room or
inside marshalling box. |
- |
Designed for high ambient temperature up to 70 °C. |
- |
Four potential free C/O contacts for Fan control, High
TemperatureAlarm, Trip & to warn against open or wrong sensor
connections. |
- |
Fully user programmable with self-test facility |
- |
Auto & Manual fan exerciser control. |
- |
Combicon
connectors for terminations |
|
|
|
|
|
|
Top |
|
|
|
|
|
|
|
|
|
Transformer Protection Relay (WTS) |
|
|
|
TR-7560 |
|
|
|
|
- |
Three
channel winding temperature scanner. |
- |
Designed for monitoring temperature of all the three phase
windings. |
- |
Two potential free NO contacts for High Temperature Alarm &
Trip. |
- |
Two
analog outputs 0-1mA and 4-20mA signal. |
- |
Options of different auxiliary supply voltages. |
|
|
|
|
|
|
Top |
|
|
|
|
|
|
|
|
|
|
Transformer
Protection Relay (WTS) |
|
|
TR-7570 |
|
|
|
- |
Four
channel µC based winding temperature scanner. |
- |
Designed for monitoring temperature of all the three phase
windings and core of medium voltage cast resin / dry type transformer. |
- |
Four potential free C/O contacts for Fan control, High
Temperature Alarm, Trip & to warn against open or wrong sensor
connections. |
- |
One analog output 4-20mA signal (Optional). |
- |
Options of different auxiliary supply voltages. |
- |
TR-7570-C, a variant model is available with Isolated RS-485
interface with Modbus RTU protocol in lieu of 4-20mA signal. |
|
|
|
|
|
|
Top |
|
|
|
|
|
|
|
|
|
|
|
|
|
Transformer Protection Relay (WTS) |
|
|
|
TR-7576 |
|
|
|
|
- |
Six
channel µC based winding temperature scanner. |
- |
Designed for monitoring six critical temperature parameters on the transformer, like three windings and core or 6 winding points either 3 from primary and 3 from secondary or 3 from top and 3 from bottom of the three phase windings). |
- |
Designed for high ambient temperature up to 70 °C. |
- |
Four potential free NO contacts for Fan control, High Temperature Alarm, Trip & to warn against open or wrong sensor connections. |
- |
Fully user programmable with self-test facility |
- |
Auto fan exerciser control. |
- |
Options of different auxiliary supply voltages. |
- |
TR-7576-C, a variant model is available with Isolated RS-485 interface with Modbus RTU protocol in lieu of 4-20mA signal. |
|
|
|
|
|
|
Top |
|
|
|
|
|
|
|
|
Transformer Protection Relay (WTS)
|
|
|
|
TR-7578 |
|
|
|
|
- |
Eight
channel µC based winding temperature scanner. |
- |
Designed for monitoring eight critical temperature parameters on thetransformer,
like three windings and core or 6 winding points (either 3
from primary and 3 from secondary or 3 from top and 3 from
bottom of the three phase windings) plus core temperature and/or enclousure temperature.
|
- |
Designed for high ambient temperature up to 70 °C. |
- |
Four potential free C/O contacts for Fan control, High
Temperature Alarm, Trip & to warn against open or wrong sensor connections. |
- |
User programmable 4-20mA remote signal range. (for 4mA range is
–25 to 100°C & for 20mA range is 150 to 225°C). |
- |
Options of different auxiliary supply voltages. |
- |
TR-7578-C, a variant model is available with additional Isolated
RS-485 interface with Modbus RTU protocol. |
|
|
|
|
|
|
Top |
|
|
|
|
|
|
|
|
Remote Winding
Temperature Indicator
|
|
|
|
RWTI-400M (using 4-20mA signal) |
|
|
|
|
- |
µC based design. |
- |
Compatible with our models TR-7544, TR-7560, TR-7570, TR-7576, TR-7578 and TR-7578-C. |
- |
Accepts one 4-20mA from PECON WTS models or any other 4-20mA signal and displays the termperature. |
- |
Provides one repeat isolated current signal of 4-20mA of winding temperature for SCADA/DAS or for additional indication. |
- |
Desinged for flush mounting on panel in control room. |
|
|
|
|
|
|
Top |
|
|
|
|
|
|
|
|
Remote Winding
Temperature Indicator
|
|
|
|
RWTI-400C (using RS-485 communication) |
|
|
|
|
- |
µC based design. |
- |
Compatible with our models TR-7544-C, TR-7570-C, TR-7576-C and TR-7578-C. |
- |
Acquires current & maximum temperature data of all channels, status of relays and set-points using RS-485 communication port and diplays the same using two displays. |
- |
Provides one repeat isolated current signal of 4-20mA of winding temperature for SCADA/DAS or for additional indication. |
- |
Desinged for flush mounting on panel in control room. |
|
|
|
|
|
|
Top |
|
|
|
|
|
|
|
|
Remote Winding
Temperature Indicator
|
|
|
|
RWTI-400 (using 4-20mA signal) |
|
|
|
|
- |
Solid State Design. |
- |
Digital display offers unambiguous display. |
- |
Indications provided for no signal, under-range and over-range. |
- |
Setting provided for zero and span adjustment. |
|
|
|
|
|
|
Top |
|
|
|
|
|
|
|
|
RTD Sensor
|
|
|
|
S-02 |
|
|
|
|
- |
Suitable for all our WTI / WTS. |
- |
3
wire, PT-100 type sensor (IEC-60751, Class B) |
- |
Temperature range : -50 to 200 °C |
- |
Standard lead length : 1 meter. (Other lengths available on
demand). |
- |
Dielectric Strength : 2KVAC rms for 1 min. |
|
|
|
|
|
|
Top |
|
|
|
|
|
|
|
|
|
|